SPECIFICATIONS TEMPERATURE RANGE -55°C to +85°C with full rated voltage applied. To +125°C with 50% of rated voltage. INSULATION RESISTANCE At 25°C after 2 minutes of electrification at rated voltage or 500 VDC, whichever is less, the minimum product of Insulation Resistance and Capacitance shall be 50,000 megohms-microfarads, but need not exceed 50,000 megohms. DISSIPATION FACTOR Shall not exceed 0.3% when measured at 25°C and 1000 Hz, ±20 Hz. See characteristic curves for D.F. ratings at other temperatures. CAPACITANCE AND TOLERANCE Shall be measured within the tolerance limits specified. Measurements will be made at 25°C and 1000 Hz, ±20 Hz. LIFE TEST Shall withstand 140% of rated voltage at 85°C for 250 hours. One failure in twelve shall be permitted. Failure is defined as catastrophic (open or short). CAPACITANCE STABILITY (DRIFT) Less than 0.3% when measured in the following manner: three capacitance readings at 25°C, each made prior to and after temperature cycling from room to 85°C, and room to -55°C. The mathematical difference between the two extremes, divided by the intermediate value, and then multiplied by 100, yields the stability expressed in percent. HUMIDITY RESISTANCE Capable of meeting requirements of Mil-C-19978 and Mil-C-39022 when tested in accordance with Method 106 of Mil-STD-202. LEAD PULL AND BEND TEST Steady pull of 5 pounds applied axially to leads for one minute. Bend test shall consist of one bend from the point of egress, first 90° in one direction, back to the original axial position, and then 90° in the opposite direction with no evidence of breakage.
|
TYPE 41MPC
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| CAP. (µF) |
|
|
|
|||||||||||||||||||
|
.012 .015 .018 .022 .027 |
|
|
|
|||||||||||||||||||
|
.033 .039 .047 .056 .068 |
|
|
|
|||||||||||||||||||
|
.082 .1 .12 .15 .18 |
|
|
|
|||||||||||||||||||
|
.22 .27 .33 .39 .47 |
|
|
|
|||||||||||||||||||
|
.56 .68 .82 1.0 1.25 |
|
|
|
|||||||||||||||||||
|
1.50 1.80 2.0 3.0 4.0 |
|
|
|
|||||||||||||||||||
|
5.0 8.0 10.0 15.0 20.0 |
|
|
|
|||||||||||||||||||
|
25.0 30.0 |
|
|
|
|||||||||||||||||||
| Lead material: Tinned copper solid wire | |
| STANDARD LEAD SIZES: | # 24 AWG: (.020")-.195" Dia. # 22 AWG: (.025")-.235" and .312 Dia. # 20 AWG: (.032")-.400" Dia and up |
| FOR ONE END GROUNDED: Subtract .062" from L dimension and change part # to 46MPC. TO ADD SLEEVE: Add suffix "S" to part number and increase dimensions to: D = +.015" and L = +.062" CAPACITY TOLERANCE: STANDARD…+ 10% / OTHER…from ± 20% to ± 1% OTHER VALUES AS WELL AS VOLTAGE RATINGS ARE AVAILABLE ON REQUEST. FOR TECHNICAL CURVES (I.R. VS. TEMP., D.F. VS. TEMP., CAP CHANGE VS. TEMP.), SEE PAGE 10. |
|