Types 32MM/33MM
|
||
|
SPECIFICATIONS
200% of rated voltage applied through a minimum limiting resistance of 100 Ohms/Volt. Duration of voltage stress shall be 15 seconds minimum and 1 minute maximum at 25°C.
–55°C to +85°C with full rated voltage applied. To +125°C with 50% of rated voltage.
At 25°C after 2 minutes of electrification at rated voltage or 500 VDC, whichever is less, the minimum product of Insulation Resistance and Capacitance shall be 30,000 megohms-microfarads, but need not exceed 30,000 megohms.
Shall not exceed 1.0% when measured at 25°C and 1000 Hz, ±20 Hz. See characteristic curves for D.F. ratings at other temperatures.
Shall be measured within the tolerance limits specified. Measurements will be made at 25°C and 1000 Hz, ±20 Hz.
Shall withstand 140% of rated voltage at 85°C for 250 hours. One failure in twelve shall be permitted.
Less than 0.3% when measured in the following manner: three capacitance readings at 25°C, each made prior to and after temperature cycling from room to 85°C, and room to –55°C. The mathematical difference between the two extremes, divided by the intermediate value, and then multiplied by 100, yields the stability expressed in percent. |