Metallized Polyester Capacitors

  
Types 32MM/33MM


 


SPECIFICATIONS



DIELECTRIC WITHSTANDING VOLTAGE

200% of rated voltage applied through a minimum limiting resistance of 100 Ohms/Volt. Duration of voltage stress shall be 15 seconds minimum and 1 minute maximum at 25°C.




TEMPERATURE RANGE

–55°C to +85°C with full rated voltage applied. To +125°C with 50% of rated voltage.




INSULATION RESISTANCE

At 25°C after 2 minutes of electrification at rated voltage or 500 VDC, whichever is less, the minimum product of Insulation Resistance and Capacitance shall be 30,000 megohms-microfarads, but need not exceed 30,000 megohms.




DISSIPATION FACTOR

Shall not exceed 1.0% when measured at 25°C and 1000 Hz, ±20 Hz. See characteristic curves for D.F. ratings at other temperatures.




CAPACITANCE AND TOLERANCE

Shall be measured within the tolerance limits specified. Measurements will be made at 25°C and 1000 Hz, ±20 Hz.




LIFE TEST

Shall withstand 140% of rated voltage at 85°C for 250 hours. One failure in twelve shall be permitted.




CAPACITANCE STABILITY (DRIFT)

Less than 0.3% when measured in the following manner: three capacitance readings at 25°C, each made prior to and after temperature cycling from room to 85°C, and room to –55°C. The mathematical difference between the two extremes, divided by the intermediate value, and then multiplied by 100, yields the stability expressed in percent.

 

FEATURES

  • Wrap and fill construction
  • Tubular or oval configuration for optimum space savings
  • Extended foil design
  • Miniature size — lightweight
  • Low dissipation factor
  • Excellent stability
  • Quality control procedures per Mil-Q-9858

 

APPLICATIONS

  • Data Processing Equipment
  • Aircraft and Missile Systems
  • Industrial Instrumentation
  • Navigation and Distance Measuring Equipment
  • Communications equipment
  • Tachometers
  • Filters
  • Peripheral Equipment





HUMIDITY RESISTANCE
Meets requirements of Mil-C-27287, Para. 3.12 when tested in accordance with Mil-STD.-202, Method 103 B, Condition B.



LEAD PULL AND BEND TEST
Steady pull of 5 pounds applied axially to leads for one minute. Bend test shall consist of one bend from the point of egress, first 90° in one direction, back to the original axial position, and then 90° in the opposite direction with no evidence of breakage.