Polypropylene Capacitors

Type 32PL
 
&nbsp


SPECIFICATIONS



DIELECTRIC WITHSTANDING VOLTAGE

200% of rated voltage applied through a minimum limiting resistance of 100 Ohms/Volt. Duration of voltage stress shall be 15 seconds minimum and 1 minute maximum at 25°C.




INSULATION RESISTANCE

At 25°C after 2 minutes of electrification at rated voltage or 500 VDC, whichever is less, the minimum product of Insulation Resistance and Capacitance shall be 250,000 megohms-microfarads, but need not exceed 250,000 megohms.




DISSIPATION FACTOR

Shall not exceed .05% when measured at 25°C and 1000 Hz, ±20 Hz. See characteristic curves for D.F. ratings at other temperatures.




CAPACITANCE AND TOLERANCE

Shall be measured within the tolerance limits specified. Measurements will be made at 25°C and 1000 Hz, ±20 Hz.




LIFE TEST

Shall withstand 140% of rated voltage at 105°C for 250 hours. One failure in twelve shall be permitted.




TEMPERATURE COEFFICIENT

Capacitance shall change linearly over operating temperature range range of -55°C to +85°C at rate of -290, ±75 parts per million/°C.




CAPACITANCE STABILITY (DRIFT)

Less than .2% when measured in the following manner: three capacitance readings at 25°C, each made prior to and after temperature cycling from room to 105°C, and room to -55°C. The mathematical difference between the two extremes, divided by the intermediate value, and then multiplied by 100, yields the stability expressed in percent.

 

FEATURES

  • Wrap and fill construction
  • Excellent long-term stability
  • Superior "Q" for tuned circuits
  • High insulation resistance
  • Linear temperature coefficient (-55°C to +85°C)
  • Quality control procedures per Mil-Q-9858
  • Extended foil design

 

APPLICATIONS

  • Computers
  • Data Processing Equipment
  • Aircraft and Missile Systems
  • Industrial Instrumentation
  • Navigation and Distance Measuring Equipment
  • Communications Equipment
  • Timing and Retrace Circuits
  • Integrating Networks
  • High "Q" Low Loss Filters
  • Peripheral Equipment

 

HUMIDITY RESISTANCE

Meets requirements of Mil-C-27287, Para. 3.12 when tested in accordance with Mil-STD.-202, Method 103 B, Condition B.

LEAD PULL AND BEND TEST

Steady pull of 5 pounds applied axially to leads for one minute. Bend test shall consist of one bend from the point of egress, first 90° in one direction, back to the original axial position, and then 90° in the opposite direction with no evidence of breakage.

TEMPERATURE RANGE

-55°C to +105°C with full rated voltage applied.

FOR MORE INFO ON DIMENSIONS AND CHARACTERISTICS, CLICK HERE